Skip to content

Weekday orders before 2pm PT ship the same day.

KLOWLot KLOW80-S1-22280

Investigation, BTLabs report COA261420-002

KLOW80-S1-22280

KLOW 80 mg, GHK-Cu 50mg, KPV 10mg, BPC-157 10mg, TB-500 10mg

FailedInvestigation openNo vials from this lot shippedUpdated 2 Nov 2026

BTLabs marked this lot Failed. Its test found three of the four peptides in KLOW, GHK-Cu, KPV and BPC-157, and did not report the fourth, TB-500. When we asked why, the lab told us its method was looking for full-length thymosin beta-4, not TB-500, which is a shorter fragment of it. The result is with the lab for further review.

What this means

For anyone holding KLOW, or thinking about ordering it.

TB-500 is the only thing the lab flagged. FTIR identified the other three peptides, HPLC measured each of them, and purity came in at 99.7% against a 98% minimum. Nothing else on the report was marked as a problem.

Blends with TB-500 are routine for us. It sits alongside BPC-157 in TB10, and alongside GHK-Cu and BPC-157 in GLOW, and labs have measured it in both. Labs just don’t all test for it the same way: one reports it as thymosin beta-4, another looked for the full-length chain. That is what happened here, and BTLabs is continuing to work on it.

Even if TB-500 had been missing, we would be comfortable selling this lot, labelled plainly as a GHK-Cu, BPC-157 and KPV blend with this report beside it. For now, no vials from this lot have shipped while the lab finishes its work.

What failed

What BTLabs reported for each peptide, against what the label says.
PeptideOn the labelReported by BTLabs
GHK-Cu50 mg48.3 mg
KPV10 mg10.1 mg
BPC-15710 mg13.0 mg
TB-50010 mgNot reported
HPLC purity
99.7%, against a specification of at least 98%
Identity by FTIR
Confirms GHK-Cu, KPV and BPC-157
Sample
BTL260901-008-002, tested 9 Sep 2026
Result on the report
Failed

Investigation

Each step, in order, with its date where we have it. New steps are added at the bottom.
  1. 19 Sep 2026

    The lab reports a failure

    BTLabs tests sample BTL260901-008-002 and issues report COA261420-002, marked Failed. FTIR and HPLC confirm GHK-Cu, KPV and BPC-157, at 99.7% HPLC purity. TB-500 is not reported.

  2. 2

    We ask the lab why

    The only thing missing was TB-500, so we asked BTLabs how they had tested for it.

  3. 3

    BTLabs acknowledges oversight

    Their method was looking for full-length thymosin beta-4, a 43-amino-acid peptide. TB-500 is a short synthetic fragment of it, so a search for the full chain would not find it.

  4. Next

    We are waiting on the lab’s review. When it’s done we’ll post the outcome here, with any revised report next to the original. The original stays published either way.

The sample tested

The lab's own photo of the vial it tested, and the lot line from its report.
BTLabs photo of the KLOW sample tested for lot KLOW80-S1-22280

Printed on the BTLabs report

Lot KLOW80-S1-22280, as printed on the report

Never sold. No vials from this lot shipped. KLOW shipping now is from lot KLOW-1WTY1V, which passed.

BTLabs, tested 29 Oct 2026, 99.7% HPLC purity

The full report

Every page, as the lab issued it, including the chromatogram.
Page 1 of 2
BTLabs report COA261420-002 for lot KLOW80-S1-22280, page 1
Page 2 of 2
BTLabs report COA261420-002 for lot KLOW80-S1-22280, page 2

Questions about this lot

Ask us

Message us about this lot or this investigation. A person replies.

Message us on WhatsApp

Ask the lab

The report is hosted on BTLabs's own website, so you can check it with them directly.

Verify at BTLabs

Test it yourself

Send any sealed PepGuys vial to a lab on our approved list. We pay the fee and publish the result.

Retest Promise

All investigations